H20-923_V1.0 Exam Questions & Answers

HCSP-Field-Data Center Facility V1.0  •  Huawei

60 Questions Updated Sep 2026 99% Pass Rate
Get Full Access

100% money-back guarantee

Sample H20-923_V1.0 Questions

Practice with real exam-style questions, each with the verified correct answer and explanation.

Q1 MultipleChoice

Operators can view parameters and set parameters on the "User Settings" and "Comm Settings" menus.

Correct Answer: A
Explanation:

On Huawei data center cooling/monitoring controllers, menu permissions are typically organized so that routine O&M staff (operator role) can perform day-to-day adjustments that are required for normal running and integration, without accessing factory-only commissioning items. The User Settings menu is designed for operational configuration such as target temperature/humidity setpoints, control preferences, and other user-level parameters that need to be tuned to match the data hall environment and load changes. The Comm Settings menu is intended for communication configuration used in site integration, such as setting communication addresses, baud rates, protocol-related parameters, or enabling interfaces needed for upper-layer systems (for example, monitoring platforms). These settings are considered part of normal operation management and must be accessible so operators can maintain monitoring connectivity, replace controllers, or restore communication after changes. Higher-risk parameters (for example, factory calibration, protected control logic, or deep commissioning values) are normally restricted to higher privilege roles, but viewing and setting parameters within User Settings and Comm Settings is an operator-allowed function.

Q2 MultipleChoice

The rated output capability of a single power module for the UPS5000-H is how many kVA.

Correct Answer: B
Explanation:

Huawei UPS5000-H is a modular UPS platform built by paralleling standardized power modules inside the power cabinet to form different system capacities. In this architecture, the ''single power module'' is the basic building block that contributes a fixed rated apparent power to the total UPS capacity. For the UPS5000-H series, each power module is rated at 100 kVA, and the system capacity is achieved by installing multiple 100 kVA modules and configuring redundancy (such as N+1). This modular approach improves availability and O&M efficiency because a failed module can be isolated and replaced without shutting down the entire UPS, while the remaining modules continue carrying the load within their capacity limits. Using 100 kVA as the module rating also simplifies planning: technicians can quickly estimate remaining headroom by counting active modules and comparing total available kVA/kW against the real-time load, ensuring the UPS stays within recommended loading and redundancy margins during maintenance or fault conditions.

Q3 MultipleChoice

After replacing the fan, choose "Menu > _____ > Performance Maintenance" on the main screen to enter the "Performance Maintenance" screen and clear the accumulated runtime of the indoor fan.

Correct Answer: D
Explanation:

In Huawei room air conditioner and precision cooling unit O&M, fan replacement is treated as a maintenance activity that must be recorded in the controller so lifecycle management remains accurate. The controller tracks accumulated runtime for wear components such as indoor fans to support preventive maintenance planning, alarm thresholds, and performance analysis. After a fan is replaced, the old runtime value must be cleared so the system can correctly measure the new fan's service hours, avoiding premature ''maintenance due'' prompts or misleading reliability assessments. This function belongs to the maintenance function set rather than alarm viewing, parameter settings, or basic running status. Therefore, the correct navigation is through Menu > Maint > Performance Maintenance, where the technician can locate the indoor fan runtime item and reset/clear it after confirming the replacement. Performing this step ensures consistent O&M records, supports correct maintenance intervals, and helps troubleshooting by aligning future fan-related alarms with the actual operating hours of the newly installed component.

Q4 MultipleChoice

If the SPD indicator of a smart module is green, the SPD is running properly. If the SPD indicator is red, the SPD is faulty and must be replaced immediately.

Correct Answer: A
Explanation:

In Huawei data center power distribution design, the SPD (Surge Protective Device) provides overvoltage surge protection for sensitive loads by diverting transient energy to ground through internal protection components. The SPD status indicator is used for O&M judgment of protection availability. When the indicator is green, it indicates the SPD protection components are within normal working condition and the surge protection path remains effective. When the indicator turns red, it typically means the SPD's internal protection element has degraded or disconnected (end-of-life or failure after cumulative surges), and the device can no longer provide the rated protection level. In this condition, the distribution system is left exposed to surge risk, especially during thunderstorms, switching operations, or upstream disturbances. Therefore, Huawei O&M practice treats a red SPD indicator as a replacement trigger, requiring immediate corrective action: confirm alarm/status, ensure safe isolation following electrical safety procedures, and replace the SPD module to restore protection and maintain power system reliability.

Q5 MultipleChoice

Which O&M practice is most effective for identifying cooling inefficiency caused by airflow problems in an operating data center?

Correct Answer: B
Explanation:

Huawei facility O&M methods emphasize using monitored operating data to locate inefficiencies before they become faults. Airflow-related cooling inefficiency commonly appears as hot spots at rack inlets, elevated return air temperature fluctuations, abnormal fan speed increases, or uneven temperature distribution across aisles. By trending rack inlet temperature sensors alongside cooling unit supply/return temperatures and fan speed or airflow commands, operations teams can distinguish between insufficient cooling capacity and poor airflow organization. Recirculation (hot air returning to rack inlets) often raises localized inlet temperatures without a proportional rise in room average temperature, while bypass (cold air short-circuiting back to returns) reduces cooling effectiveness and can drive fans to higher speeds unnecessarily. Data-driven checks support targeted corrective actions such as sealing cable openings, adjusting floor tile placement, restoring containment integrity, balancing airflow, or optimizing setpoints. This approach improves thermal stability, prevents overcooling, reduces energy waste, and aligns with Huawei's emphasis on integrated monitoring and closed-loop optimization for reliable, efficient operation.

Get access to all 60 verified questions with detailed answers.

Unlock All H20-923_V1.0 Questions

Frequently Asked Questions

The H20-923_V1.0 is Huawei's HCSP-Field-Data Center Facility V1.0 certification exam that validates professionals' knowledge and skills in data center facility design, implementation, and management. This certification is designed for field engineers and technical professionals working with Huawei's data center solutions and infrastructure.

This exam is ideal for field engineers, data center technicians, infrastructure professionals, and IT specialists who work with Huawei data center facilities. Candidates should have practical experience with data center operations, cooling systems, power distribution, and facility management.

The exam covers key data center facility topics including power management systems, cooling and thermal management, physical infrastructure design, cable management, and environmental monitoring. It also includes content on data center standards, safety protocols, and best practices for facility operations and maintenance.

Preparation should include studying official Huawei training materials, taking practice exams, and gaining hands-on experience with data center facility components. Consider enrolling in Huawei's official training courses and reviewing documentation on data center standards and Huawei-specific facility solutions.

Typically, Huawei certification exams require a passing score of 60% or higher, though the exact passing score for H20-923_V1.0 may vary. It's recommended to consult Huawei's official certification website or training materials for the specific passing score requirement for this particular exam version.
Exam Details
  • Exam CodeH20-923_V1.0
  • VendorHuawei
  • Total Questions60
  • LanguageEnglish
  • Version1.0
  • Last UpdatedSep 1, 2026
4.9/5

Pass H20-923_V1.0 First Time

Get all 60 exam questions with verified answers and 90-day free updates.

Buy Now & Pass
  • PDF + Practice Test Bundle
  • 90-Day Free Updates
  • 100% Money-Back Guarantee
  • Instant Download
  • 24/7 Customer Support
99% Pass Rate Trusted by 50,000+ IT professionals