Limited-Time Offer: Enjoy 50% Savings! - Ends In 0d 00h 00m 00s Coupon code: 50OFF
Free Exam Questions

2V0-17.25 Exam Questions & Answers

VMware Cloud Foundation 9.0 Administrator  •  VMware

115 Questions 135 min Updated Sep 2026 99% Pass Rate
Get Full Access

100% money-back guarantee

Sample 2V0-17.25 Questions

Practice with real exam-style questions, each with the verified correct answer and explanation.

Q1 MultipleChoice

Which two capabilities are provided by default within Istio Service Mesh? (Choose two.)

Correct Answer: C, E
Explanation:

Istio Service Mesh provides built-in capabilities for managing service-to-service communication within Kubernetes environments.

The Istio documentation highlights default capabilities including:

Service discovery (C): Automatic detection and routing between services.

Mutual TLS (mTLS) encryption (E): Secure communication between services by default.

Istio does not provide:

Multi-cluster backup/restore (A) --- handled by tools such as Velero.

Cluster conformance validation (B).

Advanced container runtime (D) --- container runtime is handled by container engines such as containerd.

Thus, the correct answers are Service discovery and Connection encryption.

Q2 MultipleChoice

An administrator has been tasked with deploying a new VMware Cloud Foundation (VCF) instance into an existing VCF Fleet to expand the solution into a second region (Region B). The design document for the solution states:

The solution must be configured to follow the VCF Fleet with Disaster Recovery Design Model.

The VCF Instance in Region B must consist of a management domain and a single workload domain.

What component must the administrator deploy to match the solution design?

Correct Answer: A
Explanation:

In VMware Cloud Foundation 9.0, the VCF Fleet Disaster Recovery Design Model explicitly requires deployment of VMware Live Recovery (VLR) to provide:

Cross-instance disaster recovery

Site pairing between regions

Protection of management and workload domains

Orchestrated failover and failback

From the VCF 9.0 Fleet Architecture documentation:

''To implement a Fleet-level disaster recovery model across multiple VCF instances in different regions, deploy VMware Live Recovery to provide orchestration, replication, and recovery operations between paired VCF instances.''

The Fleet DR design requires:

A primary VCF instance (Region A)

A secondary VCF instance (Region B)

VMware Live Recovery to manage DR workflows across instances

Other options are incorrect:

DSM -- Provides database-as-a-service capabilities, not DR orchestration.

VCF Operations HCX -- Used for workload mobility, not DR orchestration.

VCF Operations -- Provides monitoring and observability, not DR functionality.

Document reference (VCF 9.0):

VMware Cloud Foundation 9.0 VCF Fleet Architecture Disaster Recovery Design Model

VMware Cloud Foundation 9.0 VMware Live Recovery Integration with VCF

Q3 MultipleChoice

An administrator is deploying a new VCF instance in an existing fleet. Which three components must be deployed? (Choose three.)

Correct Answer: A, D, E
Explanation:

The VCF 9.0 Deployment Guide states:

''Each new VCF instance requires its own management domain consisting of vCenter Server, NSX Manager cluster, and SDDC Manager.''

vCenter (A) is required to manage ESXi hosts and clusters.

NSX Manager (D) provides software-defined networking for the instance.

SDDC Manager (E) is the lifecycle and management component central to each VCF instance.

Supervisor (B) is optional and only enabled if Kubernetes workloads are required. VCF Automation (C) is a separate solution, not part of the core instance bring-up. VCF Installer (F) is the deployment tool, not a persistent component. Thus, the correct components to deploy are vCenter, NSX Manager, and SDDC Manager.

Q4 MultipleChoice

An administrator is responsible for a vSAN Express Storage Architecture (ESA) cluster running workloads with a RAID-6 policy. The administrator must enable auto-policy management in vSAN ES

Correct Answer: D
Explanation:

The vSAN ESA documentation in VCF 9.0 explains that auto-policy management dynamically selects the most efficient data placement policy based on cluster size. For RAID-6 (erasure coding with double parity), the minimum required host count is 6. The docs state:

''RAID-6 (Erasure Coding with FTT=2) requires a minimum of six hosts in a vSAN ESA cluster. This ensures that data and parity components can be distributed across unique failure domains.''

With fewer than six hosts, RAID-6 cannot be enforced and auto-policy management will fall back to RAID-1 mirroring. RAID-6 in vSAN ESA provides higher storage efficiency but comes with stricter host count requirements. Options 2 and 4 are far below requirements, while 8 provides more redundancy but is not the minimum. Therefore, the correct minimum number of hosts for RAID-6 with ESA is 6.

Q5 MultipleChoice

An Administrator has been tasked with deploying an Organization for All Applications within a new VMware Cloud Foundation (VCF) Automation. During the regional networking creation step, which four NSX constructs will automatically be configured? (Choose four.)

Correct Answer: A, B, C, F
Explanation:

In VMware Cloud Foundation 9.0, the introduction of the Virtual Private Cloud (VPC) model within VCF Automation (formerly Aria Automation) simplifies multi-tenancy. When an administrator creates an organization and configures regional networking, the system automates the deployment of several high-level NSX objects to provide isolated networking for that organization's applications.

According to the VCF 9.0 Automation and Networking Guide:

A Provider Tier-0 Gateway (C): This is the top-level logical router in the VCF environment. During the regional networking setup, the system identifies or configures the Provider T0 to act as the primary exit point for North-South traffic for the organization.

A Virtual Private Cloud (VPC) connectivity profile (F): This profile defines the networking 'flavor' (such as IP blocks, DNS, and security settings) that will be applied to the organization's VPCs. It acts as the template for how the VPC interacts with the provider's physical and logical infrastructure.

A Default Virtual Private Cloud (VPC) (B): Upon completing the organization setup, VCF Automation provisions a default VPC for that organization. This VPC serves as the logical container for the tenant's subnets, security groups, and routing.

An outbound Source Network Address Translation (SNAT) rule (A): To allow virtual machines within the newly created VPC to access external resources (the internet or corporate network) while using private IP space, the system automatically creates an outbound SNAT rule on the gateway associated with the VPC or the Provider T0.

Why other options are incorrect:

A Virtual Distributed Switch (VDS) (D): The VDS is a foundational component of the VCF VI Workload Domain created during Day 1 operations. It is not 'automatically configured' during the high-level regional networking step of a VCF Automation organization; it must already exist.

An NSX Transit Gateway (E): While NSX uses Tier-0 and Tier-1 gateways for transit, 'Transit Gateway' is a specific term often associated with public cloud (AWS) integrations. In the context of VCF 9.0 regional networking for a VPC, the core constructs are the T0/T1 and VPC profiles.

An outbound Destination Network Address Translation (DNAT) rule (G): DNAT is typically used for inbound traffic (mapping a public IP to a private internal IP). Outbound traffic uses SNAT to mask the internal IP as it leaves the organization.


VMware Cloud Foundation 9.0 Administration Guide: Configuring Organizations and VPCs in VCF Automation.

VMware NSX (VCF 9.0) Guide: Automated VPC Provisioning and Connectivity Profiles.

Get access to all 115 verified questions with detailed answers.

Unlock All 2V0-17.25 Questions

Frequently Asked Questions

The 2V0-17.25 is VMware's official certification exam for VMware Cloud Foundation 9.0 Administrator. It validates the skills and knowledge required to install, configure, manage, and troubleshoot VMware Cloud Foundation 9.0 environments in production settings.

The exam covers key areas including VCF architecture and components, deployment and configuration, management operations, networking and security, storage configuration, and lifecycle management. It also includes content on vSphere, vSAN, NSX-T, and vRealize Suite integration within the VCF environment.

VMware recommends that candidates have at least 6-12 months of hands-on experience with VMware Cloud Foundation or equivalent vSphere, vSAN, and NSX-T experience. Candidates should be familiar with enterprise virtualization, networking, and storage concepts.

The exam is typically 120 minutes in duration and contains approximately 70 questions in multiple-choice and drag-and-drop formats. The passing score is usually around 70%, though VMware may adjust this threshold based on exam difficulty.

VMware offers official training courses, instructor-led classes, and self-paced learning materials through VMware Learning. Additionally, candidates can use third-party study guides, practice exams, official VCF documentation, and hands-on lab environments to prepare for the certification.
Exam Details
  • Exam Code2V0-17.25
  • VendorVMware
  • Total Questions115
  • Duration135 min
  • LanguageEnglish
  • Last UpdatedSep 1, 2026
4.9/5

Pass 2V0-17.25 First Time

Get all 115 exam questions with verified answers and 90-day free updates.

Buy Now & Pass
  • PDF + Practice Test Bundle
  • 90-Day Free Updates
  • 100% Money-Back Guarantee
  • Instant Download
  • 24/7 Customer Support
99% Pass Rate Trusted by 50,000+ IT professionals