D-VXB-DY-A-24 Exam Questions & Answers
Dell VxBlock Deploy Achievement • Dell EMC
100% money-back guarantee
Sample D-VXB-DY-A-24 Questions
Practice with real exam-style questions, each with the verified correct answer and explanation.
Refer to the exhibit.
A cable with the following label was connected to the wrong equipment type:
* M91A-01:01 U61A-01:09
Based on the exhibit, what is the target equipment type?
The label on the cable indicates two parts: ''M91A-01:01'' and ''U61A-01:09''. The first part of the label ''M91A'' refers to a specific type of equipment as per the exhibit. According to the exhibit, ''M9'' corresponds to ''MDS 9xxx'', which is a Cisco Multilayer Director Switch. The second part of the label, ''U61A'', does not directly match any category in the provided list; however, it seems to be an internal reference that could be related to user-specific configurations or locations.
Since we are looking for the target equipment type and not where it was mistakenly connected, we focus on the first part of the cable label. The numbers following ''M91A'' indicate slot and port information. Therefore, based on this labeling system and referring to the exhibit provided, which lists various EMC and Cisco equipment types along with their corresponding codes (like AP for APIC Appliance or CN for Cust. Network), we can deduce that ''M91A'' stands for ''MDS 9xxx''. The subsequent numbers ''-01:01'' suggest Slot 1, Port 1.
A System Engineer is validating system cabling for a VxBlock 1000. They find that some ports on Fabric Interconnects 1A are not connected.
Which connections are missing?
What is a licensed feature of Isilon OneFS?
SMARTPOOL is a licensed feature of Isilon OneFS. It enables the automated tiering of data across different types of storage media within the cluster, optimizing performance and storage efficiency based on data usage patterns.
Dell EMC Isilon OneFS documentation.
Technical resources on Isilon features and licensing.
Which switch provides FC connectivity between Cisco UCS hosts and the storage array in a Unified Network?
The Nexus 5000 series switches provide Fibre Channel (FC) connectivity between Cisco UCS hosts and the storage array in a Unified Network. The Nexus 5000 series is designed to support both Ethernet and FC traffic, making it suitable for Unified Fabric environments.
Cisco Nexus 5000 series documentation.
Technical resources on Unified Network configurations.
A customer engineer is unable to securely connect to vCenter using their laptop. Both the vCenter and the customer laptop are behind a firewall. The network security team requests that the customer engineer provide source and destination port numbers to establish the needed connection.
What ranges of source and destination port numbers are valid?
When securely connecting to vCenter, the customer engineer needs to provide the correct source and destination port numbers. The valid source port range for secure connections is typically from 49152 to 65535, which are ephemeral ports assigned by the operating system for outbound connections. The destination port for secure connections to vCenter is 443, which is the standard port for HTTPS.
VMware vCenter documentation.
Networking standards for secure HTTPS connections.
Get access to all 76 verified questions with detailed answers.